Layout of configuration window


1. Save, Save As, Rename or Delete your configurations.

2. Choose what common settings and rebar settings should be used.

3. Define settings for selected reinforcement.


Common Settings


Minimal Rebar Length – if rebar length is less than value provided here, then it will be deleted.

Minimal Distance Between Bars – applies to rebar which has a step defined - main and U rebar, if First/Last Spacing is set to Both. Example: If Minimum distance is set to 60 and First/Last Spacing to Both and distance is 50, then:

Example: If Minimum distance is changed to 135, then:


Set Solid in View – if Rebar is created while in 3D view, Rebar visibility states will be checked as Solid in that view. If rebar is created while 2D view is active, rebar will not be set to solid.

Set Unobscured – will set Unobscured for rebar in active view


Exclude Inserts - if checked, software will neglect hosted families who has such Type parameter - Remove Family. It is useful if you have cuts as families and you want to ignore them, so reinforcement will go through them.

It's Yes/No parameter. Should be Type parameter and should be turned On in the properties of hosted element.


Create Rebar Sets - select which rebar should be created as individual bars and which one should be created as rebar sets.